Lithium Thionyl Cells are available in two different constructions bobbin and spiral wound. In both the versions, a non-aqueous electrolyte offers relatively higher impedance. The solution for the impedance problem is by increasing the surface area by accepting a wound cathode. But this solution cost is higher. The main disadvantage of spiral wound construction is reduced energy density and shorter operating life i.e. the extra surface area results in very higher self-discharge rate.
Bobbin-type Lithium thionyl chloride batteries are mostly suited for low power applications because of its high energy density, low self-discharge rate and long life up to 10 years based on the application. Bobbin lithium batteries offer a wide temperature range of -55C to +85C. high capacity in small packet makes bobbin type batteries to withstand changes in the pressure, temperature and shock make cells perfect for use in remote locations and extreme environmental conditions.
Lithium thionyl chloride(Li-SoCL2) batteries consist of metallic lithium as an anode (which is lightest of the all the metals) and a liquid cathode which comprises of a porous carbon current collector which is filled with thionyl chloride (SOCl2). The Li-SoCL2 cells offer a voltage of 3.6V and are cylindrical in Shape and available in different shapes from 1/2AA to DD format with a spiral structure for power applications and bobbin construction for prolonged discharge.
Lithium thionyl chloride batteries are the most prominent in primary family batteries which offer the highest voltage and energy, low self-discharge rate and longest storage life. These batteries are most suitable for long term applications such as metering, power devices, water, heat and gas meters and most importantly as backup power for memory ICs.
At Anode:
Li → Li+ + e-
At Cathode:
2SOCl2 + 4Li+ + 4e- →4LiCl + S + SO2
Total chemical reaction inside the cell is:
2SOCl2 + 4Li → 4LiCl + S + SO2
The higher voltage of 3.6V can be achieved by oxidation and deoxidation reaction between cathode and thionyl chloride anode.
Calculating the use period of primary lithium batteries and their life:
1. Use Time at Constant Discharge Rate
Assume:
1. Nominal capacity: 1 Ahr Battery
2. Current Value: 5 mA
Using the formula we can calculate use time given below:
Use Time = Nominal Capacity / Use Current … … … (1.1)
Applying the values in equation 1.1 we get,
Use time = 1 Ah/ 0.05 A
= 200 hrs … … …(1.2)
2. Use Time at Pulse Discharge Condition
Assume:
Battery Nominal Capacity: 1 Ahr
Base Current = 0.5 mA
1st pulse discharge = 2.5mA per 5 sec
2nd Pulse discharge = 10mA per 1 sec
Discharge cycle continuous for 10 second interval.
Consumption capacity Ahr per cycle is calculated by the formula given below:
Consumption capacity(Ahr) per cycle is = area α + area β + area γ … … … 2.1
Apply the values in the equation 2.1 we get, consumption capacity per cycle is
= {(0.01 – 0.0025) * 1/3600} +{(0.0025 – 0.0005) * 5/3600} + {0.0005 * 10/3600}
= 0.0000125 Ahr
Now the Use Time is,
Use time [hr] = Cycle Number * Time per 1 cycle
= (Nominal Capacity/ Used Capacity per cycle) * Time[Hr] per cycle
= {(2/0.0000125) * (10/360)}
= 444 hours
So the use time of the battery is 444 hours.
Our products now provide a channel of choice in the market for some of the world's leading manufactures and The track record of Elecorev batteries exemplifies their reliability, making them the preferred choice in each technology.
1031, Parswanthnagar, Jantanagar, Chandkheda, Ahmedabad -382424,
Gujarat, India.
service@elecorev.com
Elecorev Inc, USA
651,N. Broad ST., Suite 206,
Middletown DE 19709, New Castle, Delaware.
Email: info@elecorev.com
Elecorev Energy Private Limited, Shed No. 27 & 38, Fortune North Industrial Park, Bh. Gamthi Restuarant, S.P. Ring Road, Naroda, Ahmedabad – 382330, Gujarat, India
CIN Number:
U31100GJ2017PTC098667
Website:
www.elecorevenergy.com
Email:info@elecorev.com
Primary Battery Sales:
Abhishek : +91 – 7486943010
Secondary Battery Sales:
Akanksha: +91 – 7878796678
Elecorev Energy Pvt. Ltd. ©2023 all Right Reserved